Search results for "3d echocardiography"
showing 6 items of 6 documents
Assessment of the Tricuspid Valve Morphology by Transthoracic Real-Time-3D-Echocardiography
2005
Aim: To demonstrate the feasibility of transthoracic three-dimensional real-time echocardiography (3D-TTE) supplemental to routine assessments of the tricuspid valve and to analyze interrater agreement. Methods: Twenty healthy subjects and 74 patients with right ventricular failure were examined with conventional 2D and additionally 3D-TTE (SONOS 7500, Philips, Netherlands). The 3D exams were performed and recorded by one of two raters. The recordings were evaluated offline and independently by both raters for visualization of morphological and functional features of the tricuspid valve according to a subjective 3-point scale. Statistical analyses were performed for interrater agreement and…
Normal Reference Ranges for Echocardiography: Rationale, study design, and methodology (NORRE Study)
2013
International audience; BACKGROUND: Availability of normative reference values for cardiac chamber dimensions, volumes, mass, and function is a prerequisite for the accurate application of echocardiography for both clinical and research purposes. However, due to the lack of consistency in current echocardiographic 'reference values', their use for clinical decision-making remains questionable. AIMS: The aim of the 'Normal Reference Ranges for Echocardiography Study (NORRE Study)' is to obtain a set of 'normal values' for cardiac chamber geometry and function in a large cohort of healthy Caucasian individuals aged over a wide range of ages (25-75 years) using both conventional and advanced e…
Immediate effect of the MitraClip procedure on mitral ring geometry in primary and secondary mitral regurgitation.
2013
Percutaneous treatment of mitral regurgitation (MR) has been shown to reduce MR severity and improve functional outcomes. Surgical treatment of MR usually includes mitral annulus reduction. The influence of the MitraClip w on annulus geometry is not clear. We wanted to investigate whether the procedure itself reduces annulus diameter and if there may be differences between secondary or functional (SMR) and primary (PMR) MR. Methods and results We retrospectively assessed 3D echocardiography (3D-TEE) data of 55 patients acquired during the procedure shortly before and after clip placement for changes in annulus diameter and area. Measurements were done with QLAB software. Patients were categ…
Analysis of left ventricular volumes and function: a multicenter comparison of cardiac magnetic resonance imaging, cine ventriculography, and unenhan…
2013
Background: Contrast echocardiography improves accuracy and reduces interreader variability on left ventricular (LV)functional analyses inthe settingof two-dimensional (2D) echocardiography. Theneedfor contrast imaging using three-dimensional (3D) echocardiography is less defined. The aim of this multicenter study was to define the accuracy and interreader agreement of unenhanced and contrast-enhanced 2D and 3D echocardiography for the assessment of LV volumes and ejection fraction (EF). Methods: A multicenter, open-label study was conducted including 63 patients, using intrasubject comparisons to assess the agreement of unenhanced and contrast-enhanced 2D and 3D echocardiography as well as…
Direct measurement of left ventricular outflow tract by transthoracic real-time 3D-echocardiography increases accuracy in assessment of aortic valve …
2007
Evaluation of aortic valve stenosis is a major clinical application of echocardiography. The widely employed continuity equation requires determination of the left ventricular outflow tract (LVOT) area. We aimed at testing whether direct area measurement in a volume data set is superior to conventional calculation from the LVOT diameter.We performed LVOT measurement in 20 normal subjects and 83 patients with moderate to severe aortic stenosis with a transthoracic real-time three-dimensional echocardiography (3D-TTE) technique in two systolic frames. The off-line 3D-evaluation allows full choice of section planes within the acquired volume data set. The aortic valve area was calculated from …
Multiplane Two-Dimensional versus Real Time Three-Dimensional Transesophageal Echocardiography in Ischemic Mitral Regurgitation
2011
Objectives: Intraoperative three-dimensional (3D) transesophageal echocardiography (TEE) has been suggested to be a valuable technique for the evaluation of the mechanisms of ischemic mitral regurgitation (IMR). Studies comparing multiplane two-dimensional (2D) with 3D TEE reconstruction of the mitral valve using the new mitral valve quantification (MVQ) software are lacking. We undertook a prospective comparison between multiplane 2D and 3D TEE for the assessment of IMR. Methods: We evaluated echocardiographically 45 patients with IMR who underwent mitral valve surgery in our institution. 2D and 3D TEE examinations followed by a 3D offline assessment of the mitral valve apparatus were perf…